Inquiry

language

联系我们
如果您有任何疑问,请立即联系!
Home > Products > Vehicle sensor
Classify
  • CF800 fluxgate current sensor, CAN 12 V
  • CF800 fluxgate current sensor, CAN 12 V
CF800 fluxgate current sensor, CAN 12 V

市 场 价: ¥0元/个

优 惠 价: ¥0元/个

CF800 fluxgate isolated current sensor for battery management: ±800 A, 8-16 V supply, <10 mA zero error, CAN 500 kbps, 2.5 kV isolation. Specs and quotation from MIC Metering.
CF800 fluxgate current sensor, CAN 12 V

CF800 fluxgate current sensor, CAN 12 V

CF800 fluxgate current sensor (12 V, CAN 500 kbps)

A fluxgate current sensor for battery management systems: ±800 A, isolated measurement, under 10 mA zero error, 8 to 16 V supply, and a CAN output for charge and discharge current.

What it is

The CF800 measures battery current with a fluxgate core rather than a shunt: the current-carrying cable passes through the ring, the core saturates in a controlled way, and the electronics convert that into a digital reading. Nothing in the sensing path touches the battery potential, so the measurement is isolated by construction.

Where it fits

Pack-level current sensing on hybrid and pure electric vehicles, and on stationary lithium packs where the BMS has to calculate state of charge, state of health and available power. The 12 V nominal supply matches the vehicle bus.

What the BMS integrator needs

Two numbers: the CAN frame layout and the zero-point behaviour over temperature. Both are fixed and documented; the frame carries the measured current, an error bit and a receive-quality field.

Specification

TypeFluxgate, isolated current sensor
Measuring current−800 … +800 A
Supply voltage8 … 16 V DC (12 V nominal)
Supply current at 0 A70 mA at 12 V, 25 °C
Supply current at 800 A300 mA at 12 V, 25 °C
Linearity error−0.1 … +0.1 %
Zero point error±10 mA
Overall error at ±800 A±4000 mA (0.5 %)
Bandwidth100 Hz
Operating temperature−40 … +85 °C
OutputHigh-speed CAN, 500 kbps (TJA1051, CAN 2.0A/B, big endian)
Isolation resistance500 MΩ (500 V, ISO 16750-2)
AC isolation test2.5 kV RMS, 50 Hz, 1 min
Creepage distance7.2 mm
Overload / load dump24 V for 1 min / 32 V for 400 ms
Reverse polarity−50 V continuous

Frequently asked questions

Why fluxgate instead of a shunt or Hall sensor?
A fluxgate measures the field in a saturable core, so the sensing element never carries the battery current. That gives galvanic isolation, a very small zero drift (under 10 mA here) and no shunt heat to dissipate.
Can it measure charge and discharge separately?
Yes. The output is signed: −800 A to +800 A, so the BMS sees charging, discharging and rest in one reading.
How is the reading delivered?
Over CAN at 500 kbps, big-endian, in a fixed 8-byte frame. We supply the frame layout with the part so the BMS integrator can decode it directly.
  • Service Hotline

    Service Hotline

    +86 13923792185

  • WeChat

    MIC Metering (Shenzhen) Limited
  • TOP